Abus FU9001 Privest Wireless Alarm Base Set Installatio Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Für Zuhause Abus FU9001 Privest Wireless Alarm Base Set Installatio herunter. ABUS FU9001 Privest Wireless Alarm Base Set Installation User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 96
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
ABUS WIRELESS ALARM SYSTEM
INSTALLATION INSTRUCTION
These installation instructions are an important product accessory. They contain important installation and operation
information. Bear this in mind if you pass the product on to others.
Store these installation instructions in a safe place for future reference.
For a list of contents with page numbers, see page 3.
For brief instructions of starting up the ABUS wireless alarm package, see page 10-86.
Seitenansicht 0
1 2 3 4 5 6 ... 95 96

Inhaltsverzeichnis

Seite 1 - INSTALLATION INSTRUCTION

ABUS WIRELESS ALARM SYSTEM INSTALLATION INSTRUCTION These installation instructions are an imp

Seite 2 - 5INWSAIMABEN-C

3-10 3.5 How can the ABUS wireless alarm system be extended? The ABUS wireless alarm system is a modular, extendable security system. The following gr

Seite 3 - Contents

3-11 3.6 CE manufacturer’s declaration EG – KONFORMITÄTSERKLÄRUNG EC – DECLARATION OF CONFIRMITY Wir / We Security-Cen

Seite 4

4-12 Chapter 4 Initial considerations Before starting to install your new ABUS wireless alarm system, please take the time to consider the following.

Seite 5

4-13 4.1 What kinds of security are there? In general, there are three different ways of securing an object: External perimeter surveillance, in whi

Seite 6 - Chapter 2 Safety information

4-14 4.3 Where do I install the ABUS wireless alarm system? The ABUS wireless alarm system should be installed in your house near an analogue telephon

Seite 7

5-15 Chapter 5 Installing the ABUS wireless alarm system Make a sketch of the object or use the architect’s plans. Enter the absolutely necessary wir

Seite 8

5-16 5.2 How do I install the ABUS wireless alarm system? The ABUS wireless alarm system is mounted on the wall in three steps. You need a flat screwd

Seite 9

5-17 5.2.3 Fixing the faceplate Before fixing the faceplate, first read the following sections (up to page 5-20) and then return here. The preceding

Seite 10

5-18 5.5 How do I connect the other contacts in the ABUS wireless alarm system? 5.5.1 Connecting a wired sounder The ABUS wireless alarm system is fit

Seite 11

5-19 NOTE: 1. You can connect external equipment to clamp N.O instead of to clamp N.C. If you connect to clamp NC (normally closed), the circuit

Seite 12

ABUS WIRELESS ALARM SYSTEM These installation instructions are published by ABUS Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affin

Seite 13

5-20 5.6 How are the standby batteries used? The ABUS alarm system is equipped with 6 standby batteries that maintain operation during a power failure

Seite 14

5-21 5.7 What are the effects of the different jumper settings? The PC board of the ABUS wireless alarm system is fitted with internal jumpers. Confi

Seite 15

6-22 Chapter 6 Programming the ABUS wireless alarm system There are several ways of programming your ABUS wireless alarm system: • At the alarm syste

Seite 16

7-23 Chapter 7 Settings in installer menu This chapter describes the options and features of the installer menu of your ABUS wireless alarm system. T

Seite 17

7-24 7.2 11 System Under System, you make settings that affect the entire system. This is an overview of the menu options according to their sequence

Seite 18

7-25 Timers: Quick-Key Parameter Default Range 11 11 22 Exit/Entry delay 2 Exit and entry delay times of Group 2. Make these settings as for Group

Seite 19

7-26 System Control: Quick-Key Parameter Default Range 11 22 0101 Quick arm YES YES/NO YES: No user PIN is necessary for activating the system o

Seite 20 - CAUTION:

7-27 System Control: Quick-Key Parameter Default Range 11 22 1111 Buzzer  Bell NO YES/NO YES: If the system is activated internally and an

Seite 21

7-28 System Control: Quick-Key Parameter Default Range 11 22 2020 Pager NO YES/NO Enables alphanumeric output of system events on a pager. The n

Seite 22

7-29 System Control: Quick-Key Parameter Default Range 11 22 2929 Global Follower NO YES/NO YES: Specifies that all zones (that are programme

Seite 23 - 00 11 33 33

Contents Chapter 1 Usage in accordance with regulations ...

Seite 24

7-30 7.2.3 11 33 Receiver Under Receiver, you can make settings that control the radio receiver of your ABUS wireless alarm system. To access the Rec

Seite 25

7-31 Receiver: Quick-Key Parameter Default Range 11 33 44 Delete detectors Deletes all trained wireless detectors simultaneously. To delete the wi

Seite 26

7-32 7.2.5 11 55 Labels Under System Label, you name the system and areas 1, 2 and 3, and change default names. To enter a new name: Use the buttons

Seite 27

7-33 System Label: Quick-Key Menu option Default Selection 11 55 22 to 11 55 44 Partitions 1 – 3 Partitions 1–3 Any 12 characters Changes the dis

Seite 28

7-34 Tamper Sound: Quick-Key Parameter Default Range 11 66 22 Speaker Volume Adjusts the volume of the integrated sounder in the event of an alarm

Seite 29

7-35 7.2.9 11 99 Version The Version menu shows the current version of the alarm system. To access the Version menu: 1. Select the main menu System

Seite 30

7-36 7.3 22 Zones The Zones menu enables you to train wireless detectors for the system, program zone types, and define zone dependencies. This is an

Seite 31

7-37 22 11 ZZZZ 44 Supervision Select whether a zone is to be monitored for regular reporting by the detectors to the alarm system. Set the monitor

Seite 32

7-38 Parameter Quick-Key Parameter Default Range Zone termination A wired zone is monitored using a weak electric current. The electric current is d

Seite 33 - for partition 1

7-39 Parameter Quick-Key Parameter Default Range 22 22 33 Zone Partition Partitions 1–3 Under Partition, you assign zones to different areas. Th

Seite 34

7.5.2 22 Partition ...

Seite 35

7-40 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 0101 Exit/Entry 1 Armed/internal A zone programmed as Exit/Entry 1 must not b

Seite 36

7-41 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 0909 I+Entry follow (Interior+Entry Follower) Armed The I+Entry follow zone

Seite 37

7-42 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 1818 Exit Termination A zone with the Exit Termination zone type behaves li

Seite 38

7-43 Zone sound Quick-Key Parameters Default Range 22 22 55 ZZZZ + 11 Silent No audible alarm is generated. An alarm is transmitted by telephone

Seite 39

7-44 7.3.3 22 33 Zone Testing Under Testing, you can check the correct functioning of zones. To access the Testing menu: 1. Select the Zones menu as

Seite 40

7-45 7.3.4 22 44 Editing Under Editing, you can copy and delete programmed zones. To access the Editing menu: 1. Select the Zones menu as described

Seite 41

7-46 Editing Quick-Key Parameter 22 44 44 Delete a partition Deletes a selected partition. All zones assigned to this partition are also deleted. 1.

Seite 42

7-47 7. After programming the type of interdependency, press to um define the time interval between 1 and 9 minutes. The menu for programming the

Seite 43

7-48 7.4 33 Outputs Under Outputs, you program the relay and transistor outputs of the system. You link different system events to the activation of t

Seite 44

7-49 Define Quick-Key Parameter 33 11 UOUO11 0404 Trouble Follow The switch output is activated if a system fault is detected. It is deactivated as s

Seite 45

1-5 Chapter 1 Usage in accordance with regulations The ABUS wireless alarm system is used for protecting flats and homes and small to medium business

Seite 46

7-50 Define Quick-Key Parameter 33 11 UOUO22 0808 Duress Follow The switch output is activated if a forced alarm is triggered on the operating panel i

Seite 47

7-51 33 11 UOUO33 Follow Zone This menu option lists events for a zone. 33 11 UOUO33 11 Zone Follow The switch output is activated if the selected

Seite 48

7-52 Output mode An output mode has to be set for every output. This table gives an overview of the different output modes: Outputs Quick-Key Paramet

Seite 49

7-53 Activation/Deactivation If the switch output follows more than one area or zone, you can use different patterns for activating and deactivating

Seite 50

7-54 7.5 44 Codes Under Codes, you can define user and installer Codes, define authorities, and assign areas. The ABUS wireless alarm system also has

Seite 51

7-55 Authority Levels The Authority Levels menu option contains settings for the following authorities: Grand Master: There is only one Grand Maste

Seite 52

7-56 7.5.2 44 22 Partition Default: Partition 1 Under Partition, you assign to user PINs partitions for which you have authority. The Grand Master is

Seite 53

7-57 7.5.4 44 44 Installer Default: 0133 With the installer PIN, you have access to the installer menu and thus the authority to change all system pa

Seite 54

7-58 7.5.6 44 66 Code Length Default: four digits Under Code Length, you can change the number of digits used (4 or 6) for the Grand Master, the Manag

Seite 55

7-59 7.6 55 Dialer The Dialer menu enables you to transmit alarms as voice text by telephone. In this menu, you also make the settings necessary for

Seite 56

2-6 Chapter 2 Safety information For damage caused by non-compliance with these installation instructions, no guarantee claims are possible. No liabil

Seite 57

7-60 Access Code and ID Quick-Key Parameter Default 55 55 11 Access code 5678 Defines an access code for remote programming. The four-digit access

Seite 58

7-61 Controls Quick-Key Menu option Default 55 66 0202 FM Enable NO YES: Enables FM (= Follow Me) transmission. (See also Follow Me, page 7-64.)

Seite 59

7-62 Controls Quick-Key Menu option Default 55 66 1010 Answering Machine Override YES YES: Answering machine override is activated. • The upload/

Seite 60

7-63 Dialer: Parameter Quick-Key Parameter Default Range 55 77 44 22 Wait 9 seconds Press 22 followed by . 55 77 55 Redial wait 30 seconds 30 or

Seite 61

7-64 Dialer: Parameter Quick-Key Parameter Default Range 55 77 99 22 UD Test Hr:00 Min:00 00-24 hours 00-59 minutes Under this option, enter the fo

Seite 62 - • Press to exit the menu

7-65 7.6.5 55 99 Follow Me (FM) Under this menu option, you define the forwarding of an alarm as a voice text to a telephone or a security service. I

Seite 63

7-66 Follow-Me Quick-Key Parameter Default 55 99 22 Events restore Defines whether a new call is made if the event (from section 5.9.1) is reset.

Seite 64 - on BTO (bell time out)

7-67 7.7 77 Key-fobs Under key-fobs, you learn how to train up to eight 4-button key-fobs with rolling code to work with the ABUS wireless alarm syst

Seite 65

7-68 7.7.2 77 22 Parameters Under Parameters, you program the function and the keys of the remote control. The four buttons of the remote control can

Seite 66

7-69 If you select the switch output function and confirm it with , you see the following on the display: Select a utility output with or and co

Seite 67

3-7 Chapter 3 Introduction to the ABUS wireless alarm system Congratulations – you made the right choice! The ABUS wireless alarm system offers you p

Seite 68

7-70 7.8 88 Keypads Under Keypads, you can assign two operating panels to the ABUS wireless alarm system. The following is an overview of the menu opt

Seite 69

7-71 7.8.2 88 22 Communication Test Under Communication Test you test the radio communication between your wireless operating panel and the system. T

Seite 70

7-72 7.9 99 Siren Under Siren, you can assign 3 sounders to the ABUS wireless alarm system. You can choose between internal wireless sounders and exte

Seite 71

7-73 7. Confirm the Write menu option with and your alarm system waits for a signal from your sounder. Send a message from the sounder. 8. Inser

Seite 72

7-74 7.9.3 99 33 Communication test Under communication test you test the radio communication between your sounder and the system. To access the commu

Seite 73

7-75 7.9.5 99 55 Tamper Mute Under Tamper Mute, you can deactivate the tamper function of the sounder for the current programming process. This enabl

Seite 74

7-76 7.10 00 Exit Programming Under Exit Programming, all your settings in the installer menu are saved and you exit the installer menu. Important: T

Seite 75

8-77 Chapter 8 Programming within the user programming menu This chapter explains an important menu option in the user menu. This menu option is for

Seite 76

8-78 8.1.1 77 11 Message structure Under Message structure, you define the sequence in which the voice messages are transmitted. To define a message

Seite 77

8-79 Voice message: message name Quick-Key Parameter Default Range Recording stops automatically after 10 seconds. If you want to stop recordi

Seite 78

3-8 3.2 What is the ABUS wireless alarm system? The ABUS wireless alarm system is an alarm system specially designed and developed for house owners an

Seite 79

8-80 Message Labels Quick-Key Parameter Default Range 77 22 33 Partition Message Press 33. You see the following on the display: Press or t

Seite 80

8-81 Message Labels Quick-Key Parameter Default Range 77 22 55 Macro Message Press 55. You see the following on the display: Press or to

Seite 81

8-82 Voice message: Message test Quick-Key Parameter Default Range 77 33 11 Send message Under this menu option, you can transmit a test message

Seite 82

8-83 8.1.4 77 44 Local Announcement Messages Under this menu option, you adapt local voice announcements to your requirements. To activate/deactivat

Seite 83

8-84 8.2 Walk test Under the Walk test menu option, you can test your installation. When the system is in walk-test mode, you can trigger detectors wi

Seite 84

9-85 Chapter 9 Accessories for your ABUS wireless alarm system The following is a list of accessories for your ABUS wireless alarm system. Wireless

Seite 85

10-86 Chapter 10 Brief guide This chapter explains the installation steps shown on the DVD for the ABUS wireless alarm package including a smoke detec

Seite 86 - Chapter 10 Brief guide

10-87 10.2 Training the detectors for the ABUS wireless alarm system 10.2.1 Installer menu of the ABUS wireless alarm system • First press the star

Seite 87

10-88 10.2.3 Programming zones You do not have to program the zones for the detectors in your package. They are already programmed for you as follows:

Seite 88

10-89 10.4 Exiting the installer menu All wireless components in the package are now trained. Your ABUS wireless alarm system is almost ready for ope

Seite 89

3-9 The following graphic gives you an overview of further function properties of your ABUS wireless alarm system:

Seite 90

10-90 • Confirm the menu option phone number 1 with the Enter button. • On the system keypad, enter the number with local area code and if necess

Seite 91

11-91 Chapter 11 Example of an installation plan The following table provides an overview of the information your installation plan should contain:

Seite 92

11-92 Partition Zone number Detector Zone type Name 1 2 3 4 5 6 7 8 9 10 11 12 13 1

Seite 93

11-93 Appendix A: Event Log Messages This appendix provides descriptions of all the Event Log messages(ver 1.2xx) EVENT MESSAGE DESCRIPTION Activat

Seite 94

11-94 EVENT MESSAGE DESCRIPTION Forced P=X Partition X is force armed Found Z=XXX Wireless zone found, zone No. XXX Func=XX C=YY Quick key function

Seite 95

11-95 EVENT MESSAGE DESCRIPTION Spec. main KP Special alarm from the WisDom emergency keys Soak fail Z=XXX Zone XXX has failed in the Soak test

Kommentare zu diesen Handbüchern

Keine Kommentare