Abus FU9075 Privest Wireless Key Switch Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
8
3. Insert the key in the cylinder and turn it clockwise to its end
stop so that the red LED lights up. Keep the key in this
position.
4. After about 3 seconds, the red and green LED flash
alternately and the transmitter sends the learn message.
5. Check that the alarm system has recognised the detector.
6. Program no supervision for this detector.
7. Program the zone as “Latch KSW” zone type. If you
program the zone as “BlLatch KSW delay, the system
starts the exit delay time following activation.
8. Switch the alarm centre back to normal operating mode.
Technical data
Dimensions (surface fitting) 85 x 114 x 42mm (WxHxD)
Protection type IP55
Weight 450g
Frequency 868.65 MHz
HF immunity 20V/m 80MHz–1GHz
Modulation AM
Supervision None
Battery 9V block
Battery lifetime Ca. 1 year
Ambient operating temperature -10°C – 50°C
The manufacturer reserves the right to make technical modifications
without prior notice.
CE declaration: www.security-center.org